Archives: Okolab Parts

H401-T-PAD

The Heated Flat Metal Plate can be positioned on any surface (Table Top, Cabinet work surface, etc) to create a temperature controlled flat surface.   Available in 3 different dimensions: H401-T-PAD-SMALL   174×234 mm H401-T-PAD-MEDIUM   297×210 mm  (A4) H401-T-PAD-LARGE  420×300 mm  (A3)   Features: T range: 27 to 45°C T sensor accuracy: ±0.1°C T accuracy on specimen: […]

H401-T-PAD-LARGE

The Heated Flat Metal Plate can be positioned on any surface (Table Top, Cabinet work surface, etc) to create a temperature controlled flat surface. Dimensions: 420×300 mm (A3) T range: 27 to 45°C T sensor accuracy: ±0.1°C T accuracy on specimen: ±0.3°C, after self calibration, if room temperature remains within ±1°C Plate calibration can be performed […]

H401-T-PAD-MEDIUM

The Heated Flat Metal Plate can be positioned on any surface (Table Top, Cabinet work surface, etc) to create a temperature controlled flat surface. Dimensions: 297×210 mm (A4) T range: 27 to 45°C T sensor accuracy: ±0.1°C T accuracy on specimen: ±0.3°C, after self calibration, if room temperature remains within ±1°C Plate calibration can be performed […]

H401-T-PAD-SMALL

The Heated Flat Metal Plate can be positioned on any surface (Table Top, Cabinet work surface, etc) to create a temperature controlled flat surface. Dimensions: 174×234 mm T range: 27 to 45°C T sensor accuracy: ±0.1°C T accuracy on specimen: ±0.3°C, after self calibration, if room temperature remains within ±1°C Plate calibration can be performed in […]

OBJECTIVE HEATER

Minimize the temperature gradient caused by contact with a cold objective. Features: Automatic software calibration routine determines the optimal temperature settings to achieve the highest thermal accuracy at the sample while preventing lens overheating. Controlled via user-friendly touchscreen panel Available in 3 different sizes to fit objectives with diameter from 19 to 24mm, from 25 […]

UNO-PLUS-T-H

It includes UNO-PLUS Temperature and Humidity controller with embedded 7.3″ touch screen display, for use with premixed gas. Compatible with Okolab Objective Heaters and UNO-PLUS incubating chambers.   Technical Specs The thermal controller allows to work both in chamber and in specimen feedback mode. T range: 3°C above ambient – 60°C. Temperature accuracy is ± […]

UNO-PLUS-T-H-CO2

It includes: All-in-one T/H UNO-PLUS controller with embedded 7.3″ touch screen display, for use with both 100% CO2 or premixed Air+5%CO2. Compatible with Okolab Objective Heaters and UNO-PLUS incubating chambers. Technical Specs The thermal controller allows to work both in chamber and in specimen feedback mode. T range: 3°C above ambient – 60°C. Temperature accuracy is […]

UNO-PLUS-T

It includes Temperature only controller with embedded 7.3″ touch screen display. Compatible with Okolab Objective Heaters and UNO-PLUS incubating chambers.   Technical Specs The thermal controller allows to work both in chamber and in specimen feedback mode. T range: 3°C above ambient – 60°C. Temperature accuracy is ± 0.1°C in specimen feedback mode and ± […]

H203-T-H-CO2-ENCLOSURE

BL3 Microscope Black Enclosure — Temperature, Humidity, CO₂ and O₂ controller. The bundle includes: BL3 black microscope enclosure temperature controller CO₂ module built-in vibration-free humidifying module user interface   The enclosure and temperature module: Controls temperature in a large volume around the microscope. Two ductless heaters attached to the back of the enclosure provide smooth […]

H203-T-activeH-CO2-ENCLOSURE

BL3 Microscope Black Enclosure — Temperature, Active Humidity and CO₂ controller. The bundle includes: BL3 black microscope enclosure temperature module CO2 module active humidity air pump user interface   The enclosure and temperature module: Controls temperature in a large volume around the microscope. Two ductless heaters attached to the back of the enclosure provide smooth […]

H203-T-H-CO2-O2[0-21]-ENCLOSURE

BL3 Microscope Black Enclosure — Temperature, Humidity, CO₂ and O₂ controller. The bundle includes: BL3 black microscope enclosure temperature controller CO₂ and O₂ module built-in vibration-free humidifying module user interface   The enclosure and temperature module: Controls temperature in a large volume around the microscope. Two ductless heaters attached to the back of the enclosure […]

CO2-O2 Unit-BL [0-10; 0-1]

CO2-O2 Unit-BL [0-10; 0-1] connects to any Bold Line Temperature Controller and is operated by the touch screen interface OKO-TOUCH. Adds CO2 and Air to N2 CO2 range: 0-10%; O2 range: 0-1.0% CO2 Accuracy: ± 0.1 O2 Accuracy: ± 0.02% at 1% O2 after sensor calibration against a span gas with an Oxygen level within the range 0.5-1%. Okolab advises to […]

CO2-O2-UNIT-BL [0-10; 1-18]

CO2-O2-UNIT-BL [0-10;1-18] connects to any Bold Line Temperature Controller and is operated by the touch screen interface OKO-TOUCH. Adds CO2 and N2 to Air Range: CO2 0-10%; O2 1-18% (or Air) Accuracy: CO2 ± 0.1% @ 5.0%; O2 ± 0.1% @ 5.0% Repeatability: CO2 better than 0.1%; O2 better than 0.1% Set Point Resolution: CO2:0.1%; […]

CO2-O2-UNIT-BL [0-20; 1-95]

CO2-O2 Unit-BL [0-20;1-95] connects to any Bold Line Temperature Controller and is operated by the touch screen interface OKO-TOUCH. It mixes CO2, O2 and N2 with digital flow rate controllers. Mixes CO2, O2 and N2 Range: CO2 0-20%; O2 1-95% Accuracy at 5% CO2 and 5% O2: CO2 ± 0.2%; O2 ± 0.3% Set Point […]

CO2-UNIT-BL

CO2-UNIT-BL connects to any Bold Line Temperature Controller and is operated by the touch screen interface OKO-TOUCH. Adds CO2 to Air or to N2 Range: CO2 0-18% Accuracy: CO2 ± 0.1% @ 5.0% Repeatability: CO2 better than 0.1% Set Point Resolution: CO2: 0.1% Output flow rate: 0.0 – 1.0 L/min (max 0.4 L/min with OKO-AIR-PUMP-BL). […]

HUMIDITY-MODULE

Designed for checking humidity in chambers, incubators, laboratories, and to monitor indoor air quality. Features – Relative Humidity: Sensor:Hygromer HT-1 Measurement range: 0-100% Accuracy at 23°C: ±0.8% RH Response time: 18 s Features – Temperature: Sensor: Pt100 1/3DIN Class B Measurement range: -10 + 100°C Accuracy: ±0.2°C from 20 to 40°C

VOC-MODULE

Designed to measure low levels of Volatile Organic Compounds (VOCs) in ART laboratories. It allows qualification of the total VOC (TVOC) level at very low concentrations (<5 ppb). Features: Sensor Type: VOCs with IE below 10.6 eV Measurement range: 0-2000 ppb Minimum detection: 5 ppb Repeatability: ±0.5% full scale Warm up time: 10 min* Lamp […]

FLOW-RATE-MODULE

Compact and accurate flow meter with short response time, ideal for instantaneous gas flow measurements. The highly compact and lightweight design makes it ideal for many different work environments. The presence of display allows to use the sensor module also as a standalone device. Features: Sensor:MEMS Measurement range: 0-200 ml/min Accuracy: ± (2.0 reading +0.5% […]

CO2-PPM-MODULE

Designed to measure carbon dioxide at ppm in offices, laboratories, hospitals, and generally, wherever indoor air quality is important for the occupants’ comfort and health. The probe is temperature and pressure compensated. Features: Sensor: Non-dispersive infrared (NDIR) Measurement range: 0-10000 ppm Accuracy: ±(50ppm +3% reading) Response time: 2 minutes

T2-MODULE

Temperature probe, ideal for measurements of incubator temperature when sampling port access is available. T2-MODULE has an external diameter of 2 mm and is suitable for temperature measurements of bench-top and high-top incubators where the temperature monitoring port has a diameter larger than 2 mm. Features: Sensor: PT1000 RTD Class A Measurement range: 0-60°C Accuracy: […]

H401-LEICA-TL-220×170-GLASS​

The Glass T Plate creates a warm and optically transparent surface perfectly flush with the microscope stage. It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.   The glass is chemically strengthened and protected by a rigid […]

H401-LEICA10447342-GLASS/METAL

This large metal-glass heater creates a flat heating surface covering the entire stereo microscope stand. The central glass part features Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading. The wide lateral part features a second surface temperature sensor […]

H401-LEICA10447342-ROUND-GLASS

This ITO glass plate fits in the circular opening of the Leica StereoZoom with base 10447342.   It requires H401-T-CONTROLLER or H401-T-PENNY.   Features T range: ambient to 60°C T sensor accuracy: ±0.1°C T accuracy on specimen: ±0.3°C, after calibration, if room temperature remains within ±1°C Aluminium frame for superior resistance and flatness Plate diameter […]

H401-LEICA-M-HL-GLASS/METAL

This large metal-glass heater creates a flat heating surface covering the entire stereo microscope stand. The central glass part features Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading. The wide lateral part features a second surface temperature sensor […]

H401-LEICA-M-HL-GLASS

The Glass T Plate fits on the Leica M stereomicroscope base and creates a flat warm transparent surface. It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.   The glass is chemically strengthened and protected by a […]

H601-M-FRAME-GLASS

The Glass T Plate creates a warm and optically transparent surface perfectly flush with the microscope stage. It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.   H601-M-FRAME-GLASS features anti-scratch, anti-fingerprint, chemically strengthened Dragontrail glass cased in […]

H401-LEICA-R88-METAL

The Metal T Plate creates a warm flat temperature controlled surface perfectly flush with the microscope stage and features a circular observation opening in the center. It employs a surface sensor to ensure the highest accuracy on temperature reading.   It requires H401-T-CONTROLLER.   Features Flush with Leica manual 3-plate stage with 88mm circular opening […]

H601-LEICA-R88-GLASS

The Glass T Plate creates a warm and optically transparent surface perfectly flush with the microscope stage. It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.   H601-LEICA-R88-GLASS features anti-scratch, anti-fingerprint, chemically strengthened Dragontrail glass cased in […]

H401-K-FRAME-METAL-RECESSED

The Metal T Plate creates a warm temperature controlled surface recessed with the rest of the XY stage to maintain the original focal plane of the XY stage. It employes a surface sensor to ensure the highest accuracy on temperature reading.   It requires H401-T-CONTROLLER or H401-T-PENNY.   Features Fits stages with k-frame insert (160x110mm); […]

H401-K-FRAME-METAL-FLAT

The Metal T Plate creates a warm flat temperature controlled surface perfectly flush with the microscope stage and features a circular observation opening in the center. It employs a surface sensor to ensure the highest accuracy on temperature reading. It requires H401-T-CONTROLLER or H401-T-PENNY.   Features Flush with stages with k-frame insert (160x110mm); compatible with […]

H601-K-FRAME-METAL/GLASS

The Glass side of the Metal Glass T Plate creates a warm and optically transparent surface perfectly flush with the microscope stage. It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading. The glass is chemically strengthened and […]

H601-K-FRAME-GLASS-RECESSED

The Glass T Plate creates a warm and optically transparent surface perfectly recessed relative to the stage. It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.   H601-K-FRAME-GLASS-RECESSED features anti-scratch, anti-fingerprint, chemically strengthened Dragontrail glass cased in […]

H601-K-FRAME-GLASS-FLAT

The Glass T Plate creates a warm and optically transparent surface perfectly flush with the microscope stage. It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.   H601-K-FRAME-GLASS-FLAT features anti-scratch, anti-fingerprint, chemically strengthened Dragontrail glass cased in […]

H401-OLYMPUS-SZX2B-GLASS/METAL

This large metal-glass heater creates a flat heating surface covering the entire stereo microscope stand. The central glass part features Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading. The wide lateral part features a second surface temperature sensor […]

H401-OLYMPUS-SZX2B-GLASS

This ITO glass plate fits on the Olympus SZX stereo microscope base and creates a flat warm surface.   It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.   The glass is chemically strengthened and protected by […]

H401-OLYMPUS-SZX2A-GLASS/METAL

This large metal-glass heater creates a flat heating surface covering the entire stereo microscope stand. The central glass part features Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading. The wide lateral part features a second surface temperature sensor […]

H401-OLYMPUS-SZX2A-GLASS

This ITO glass plate fits on the Olympus MVX and SZX stereo microscope base and creates a flat warm surface.   It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.   The glass is chemically strengthened and […]

H601-OLYMPUS-IX3-SVR-GLASS/FRAME

H601-OLYMPUS-IX3-SVR-GLASS/FRAME is a dual channel plate featuring Indium Tin Oxide (ITO) coated glass cased in a heated aluminium frame.   It provides a warm and optically transparent surface perfectly flush with the microscope stage with the best possible temperature uniformity and accuracy, achieved by controlling the temperature of both the glass and the metal frame. […]

H401-OLYMPUS-IX-SUSP-T-PAD – FULL STAGE HEATER

The Stage Heater covers the entire GX-SFR and IX2-SFR Olympus stages and provides a flat, smooth surface at controlled temperature. It clamps on the stage and it is fixed in place by set crews positioned on the vertical sides of the plate. The Stage Heater leaves the observation hole open.   It is possible and […]

H401-OLYMPUS-IX-SUSP-METAL

The Metal T Plate creates a warm flat temperature controlled surface perfectly flush with the microscope stage and features a circular observation opening in the center. It employs a surface sensor to ensure the highest accuracy on temperature reading.   It requires H401-T-CONTROLLER or H401-T-PENNY.   Features Flush with Olympus stages: IX-SUSP, GX-SVR, GX-SFR, BX3-SSU, […]

H601-OLYMPUS-IX-SUSP-GLASS/FRAME

H601-OLYMPUS-IX-SUSP-GLASS/FRAME is a dual channel plate featuring Indium Tin Oxide (ITO) coated glass cased in a heated aluminium frame.   It provides a warm and optically transparent surface perfectly flush with the microscope stage with the best possible temperature uniformity and accuracy, achieved by controlling the temperature of both the glass and the metal frame. […]

H601-OLYMPUS-IX-SUSP-GLASS

The Glass T Plate creates a warm and optically transparent surface perfectly flush with the microscope stage. It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.   H601-OLYMPUS-IX-SUSP-GLASS features anti-scratch, anti-fingerprint, chemically strengthened Dragontrail glass cased in […]

H401-NIKON-NI-S-E-METAL

The Metal T Plate creates a warm flat temperature controlled surface at the same height as the rest of the XY stage perfectly flush with the microscope stage.   It employs a surface sensor to ensure the highest accuracy on temperature reading.   It requires H401-T-CONTROLLER or H401-T-PENNY.   Features Fits on Nikon upright microscope […]

H401-GLASS TABLE

The ITO glass table realizes a flat and transparent surface at controlled temperature. Ideal for stereo microscopes.   It requires H401-T-CONTROLLER or H401-T-PENNY.   Features T range: ambient to 60°C T sensor accuracy: ±0.1°C T accuracy on specimen: ±0.3°C, after self calibration, if room temperature remains within ±1°C 4.3” touch screen interface On-board data logging […]

H401-NIKON-SMZSS-GLASS/METAL

This large metal-glass heater creates a flat heating surface covering the entire stereo microscope stand. The central glass part features Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading. The wide lateral part features a second surface temperature sensor […]

H401-NIKON-SMZSS-GLASS

This ITO glass plate fits on the NIKON SMZSS stereo microscope base and creates a flat warm surface.   It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.   The glass is chemically strengthened and protected by […]

H401-NIKON-SMZSL-GLASS/METAL

This large metal-glass heater creates a flat heating surface covering the entire stereo microscope stand. The central glass part features Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading. The wide lateral part features a second surface temperature sensor […]

H401-NIKON-SMZSL-GLASS

This ITO glass plate fits on the NIKON SMZSL stereo microscope base and creates a flat warm surface. It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.   The glass is chemically strengthened and protected by a […]

H401-NIKON-SMZ25-GLASS/METAL

his large metal-glass heater creates a flat heating surface covering the entire stereo microscope stand. The central glass part features Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading. The wide lateral part features a second surface temperature sensor […]

H401-NIKON-SMZ25-GLASS

This ITO glass plate fits on the NIKON SMZ25 stereo microscope base and creates a flat warm surface.   It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.   The glass is chemically strengthened and protected by […]